Vistec USB Devices Driver



You must install the Altera® USB-BlasterTM or Altera USB-Blaster IIdownload cable driver before you can use it to program devices with Quartus® Prime software.

The first time the USB-Blaster download cable is plugged in, the Windows Found New Hardware dialog box prompts you to install the driver. (Note: Do not use the Add HardwareWizard from the Control Panel.)

The USB-Blaster II device drivers require manual installation so that the cable will be properly recognized. Refer to the instructions below.

The Altera On-Board USB-Blaster II cable appears as Altera USB-Blaster (unconfigured) when first attached to your system. After it has been configured by the Quartus Prime software, it will appear as Altera USB-Blaster II (JTAG interface) and then Altera USB-Blaster II (SystemConsole interface). You might need to install drivers for each of these interfaces; follow the steps below to install the drivers.

'No device drivers were found' when installing Windows 10 using a USB I have just finished a PC build and when booting windows it tells me 'No device drivers were found'. Many users have said simply to switch USB ports to 2.0 ports but my PC case is a newer model and only has USB 3.0 ports. These drivers are not needed for newer Garmin devices that use a USB mass storage or Media Transfer Protocol (MTP) interface. These devices (which include the nuvi and zumo series) use drivers that are included with Microsoft Windows. The drivers for Garmin Mode devices are included with the latest versions of Garmin Express and Garmin WebUpdater. This release brings the 1st Generation Scarlett Range, iTrack Solo and Saffire 6 USB 2.0 up to the same driver versions as the 2nd and 3rd Generation Scarlett ranges and the Clarett USB range. 1st Generation Scarlett 6i6, 8i6, 18i6, 18i8 and 18i20 continue to be supported by Scarlett Mix Control 1.10.

USB

You must have system administration (Administrator) privileges to install the USB-Blaster and USB-Blaster II download cable driver.

Vistec USB devices driver

Vistec Usb Devices Driver Vga

Driver Installation for Altera USB-Blaster

  1. Plug the USB-Blaster download cable into your PC. The Found New Hardware dialog box appears.
  2. Select Locate and install driver software (recommended).
  3. Select Don't search online.
  4. When you are prompted to Insert the disc that came with your USB-Blaster, select I don’t have the disc. Show me other options.
  5. Select Browse my computer for driver software (advanced) when you see the Windows couldn’t find driver software for your device dialog box.
  6. Click Browse, and browse to the<Path to Quartus Prime installation>driversusb-blaster directory.
    • Note: Do not select the x32 or x64 directories.
  7. Click OK.
  8. Select the Include subfolders option, and click Next.
  9. If you are prompted Windows can’t verify the publisher of this driver software, select Install this driver software anyway in the Window Security dialog box. The installation wizard guides you through the installation process.
  10. When The software for this device has been successfully installed dialog box appears, click Close.
  11. To complete your installation, set up programming hardware in the Quartus Prime software.

Vistec Usb Devices Driver Adapter

Driver

Driver Installation for Altera USB-Blaster II

Vistec Usb Devices Drivers

  1. Plug the USB-Blaster II cable into your PC.
  2. Open the Device Manager, and right-click on the Unknown device under the Other devices branch.
  3. Select Update Driver Software.
  4. Select Browse my computer for driver software.
  5. Enter the location of the Quartus Prime software USB-Blaster II driver files directory (<Path to Quartus Prime installation>driversusb-blaster-ii) in the Search for driver software in this location field.
  6. Click Next.
  7. Click Install in the Would you like to install this device software? Windows security dialog box.
  8. Close the Update Driver Software - Altera USB-Blaster II (Unconfigured) successful installation notification. The Device Manager now shows a new branch called JTAG cables with an Altera USB-Blaster II (Unconfigured) node.
  9. Open the Quartus Prime Programmer. Within a few seconds, the JTAG cables branch displays two nodes: Altera USB-Blaster II (JTAG interface) and Altera-USB Blaster II (System Console interface).